IsoMotion: displacement monitoring for seismic isolators

IsoMotion measures the relative horizontal displacement between the substructure and the superstructure of seismically isolated buildings. A telescopic rod is combined with a high-resolution inclinometer; the measured deviation angle is converted to displacement in the X and Y directions.

Ask about IsoMotionIsoMotion displacement sensor for seismic isolators

Measurement principle

Displacement is calculated as x = L·sin(θx) and y = L·sin(θy), where L is the rod length. The full trigonometric conversion is used, so accuracy is kept at large displacements.

No sliding contact

Unlike linear potentiometers, there is no sliding contact to wear.

Specifications

Measurement range
±900 mm (depends on rod length)
Lateral displacement accuracy
< 0.1 mm
Axes
2 (X, Y)
Outputs
Modbus RS485, 4–20 mA
Supply voltage
12–24 V DC
Operating temperature
−20 to +70 °C
Body
Stainless steel

Typical applications

Seismically isolated hospitals, data centres, bridges and viaducts, and industrial facilities with isolated foundations.

Integration

Connects to SCADA and building management systems and sends data to the Healthy Structures IoT Platform. Alarms are raised when displacement limits are exceeded.