Solutions · Energy

Structural health monitoring for wind turbine towers and foundations

Tower vibration and foundation tilt, followed over time, show changes in a turbine's structure early and tell the operator which towers to inspect first after a storm or an earthquake.

Request a quoteWind turbine tower and nacelle seen from below

Why monitor the tower and foundation

A wind turbine tower works under cyclic wind and rotor loads for its whole service life. Excessive tower vibration contributes to fatigue, and foundation problems show up as tilt. Tracking the tower's natural frequencies and the foundation's tilt over time reveals changes before they become visible.

After a storm or an earthquake

On a wind farm with many turbines, the operator needs to know which towers to inspect first. Comparing each tower's measurements before and after the event gives a starting order for inspection, based on data from every instrumented tower.

What is measured

Tower vibration
StructSense accelerometer nodes, three axes
Natural frequencies and damping
Modal analysis in the Healthy Structures IoT Platform
Foundation and tower tilt
Struct-Tilt: accuracy ±0.03° (0–90°), resolution 0.005°; two-axis tilt measurement in StructSense
Strain at the tower base and foundation
MAS strain gauges
Alarms and reports
Customisable alarms, event reports and monthly maintenance reports from the platform

The system monitors the tower and foundation structure. It does not replace the turbine manufacturer's condition monitoring of the drivetrain.