Static Digital Twin: automatic structural analysis with measured earthquake data
A structural analysis model describes how a building is expected to behave; monitoring data shows how it actually behaves. StructHEALTH's Static Digital Twin connects the two. It is offered as a package within the Healthy Structures IoT Platform.
Ask about the Static Digital Twin
How it works
Data acquisition
StructSense accelerometer and tilt sensors installed in the building send the measured acceleration to the cloud in real time.
Analysis
The measured acceleration is applied to the building's structural model through the ETABS API, and an elastic analysis runs automatically.
Reporting
For each structural member (columns and beams), demand is compared with capacity, and the results are delivered as a report.
Beyond modal analysis
Conventional structural health monitoring interprets how a building vibrates: frequencies, mode shapes and damping. The Static Digital Twin goes one step further. It applies the recorded earthquake motion to the structural model and computes how each load-bearing member responds.
Engineering judgement