Solutions · Telecom

Structural health monitoring for telecom towers and masts

Tilt and vibration monitoring follows foundation movement and changes in tower behaviour remotely, so site visits can be planned where the data shows a change.

Request a quoteSteel lattice telecom tower against a blue sky

Why monitor a tower

Lattice towers and monopoles are light, slender and exposed to wind, and many stand on remote sites. Uneven foundation settlement shows as tilt; changes in the structure or its connections show as changes in vibration. In seismic regions, earthquakes add a further load. All of these can be followed without a site visit.

Remote sites

Struct-Gate, the StructHEALTH gateway with a SIM card, sends data to the Healthy Structures IoT Platform over the mobile network. Alarm limits are set on the platform, so maintenance visits can be prioritised by measured change.

What is measured

Tower tilt
Struct-Tilt: accuracy ±0.03° (0–90°), resolution 0.005°; several units can share one RS485/RS422 line of up to 500 m
Tower vibration
StructSense accelerometer nodes, three axes
Natural frequencies and damping
Modal analysis in the Healthy Structures IoT Platform
Communication
Struct-Gate gateway with SIM card
Alarms and reports
Customisable alarms, event reports and monthly maintenance reports from the platform

Products that can be used in this solution

Monitoring data supports the structural engineer's assessment. Decisions about the condition of a structure remain with the engineer.